Q-Eye Radar MT

Pulse Wave FFT Technology.

in some applications it is an advantage to have a non-contact measurement. When combining both Radar and Water level transmitter, they provide a revolutionary approach to open channel and sewer flow monitoring. Combined are pulse wave radar velocity sensing technology with ultrasonic pulse echo level sensing to measure open channel flows.

Non Contact Open Channel Flow Meter.

Sensor: 1x v-sensor (radar)
1x h-sensor (ultrasonic)
Display: 4 lines, 20 characters
Keyboard: 5 keys
Datalogger: Compact Flash Card up to 2GB
Communication: RS-232
Inputs: max. 4 x 0/4-20 mA
Outputs: max. 4 x 0/4-20 mA
2 x Relay, 1 x Pulse
Power Supply: 85-264 VAC (50/60 Hz) or 12 VDC
Enclosure: Aluminium, wall mounted

AquaProfiler®-M PRO

velocity profiling

Sensor: 2 x velocity
1 x water level
1x temperature
Frequency: 2 MHz
Range: velocity ± 5 m/s
water level (hydrostatic) 0 – 4 m
temperature 0°-40°C
Accuracy: ± 1% of measured value for value v
± 0,1% for value h (hydrostatic)
± 0,3°C for temperature
Cable: 5 or 10 m from sensor to backpack
Power Supply: rechargeable battery pack LiFePO4 6.000 mAh
Operation: +24 hours (sensor & transmitter) tablet operation depending on model used
Dimensions: 210 x 160 x 61 mm (LxWxH)
Accessories: backpack to fit all components

AquaProfiler®-M

mobile acoustic flow profiler

The AquaProfiler® is a line of acoustic flow meters for portable and permanently installed applications. The AquaProfiler® precisely measures water velocities in open channels and pipes.   With its high accuracy and competitive cost, the AquaProfiler® is a perfect choice for long-term real-time monitoring or to obtain instantaneous measurements where time savings are an important aspect. It uses advanced Doppler technology to establish the velocity in many separate space points (cells) along the measurement axis and develop the flow profile.

AquaProfiler®M

point velocity

Sensor: 1 x velocity
1 x water level
1x temperature
Frequency: 6 MHz
Range: velocity 0-3 m/s
water level (hydrostatic) 0 – 4 m
temperature 0° – 50°C
Accuracy: ± 1% of measured value for value v
± 0,1% for value h (hydrostatic)
± 0,3°C for temperature
Cable: 5 or 10 m from sensor to backpack
Power Supply: rechargeable battery pack LiFePO4 6000 mAh
Operation: +24 hours (sensor & transmitter) tablet operation depending on model used
Dimensions: Ø 45mm, length: 290 mm
Accessories: backpack to fit all components

Q-Eye PSC MT

stationary Pulse-Doppler system

For sewage treatment plants flow measurements are primarily installed for internal reasons, for example to control specific plant components with flow dependency or for controlling additives. International regulations for example the EU-Directive for handling municipal waste water require a continuous surveillance of waste water flow. Defective flow measurements on sewage-treatment plants can therefore influence their operation, but there can also be legal or environmental consequences.

Sensor: 1 x velocity
1 x water level
Frequency: 1 MHz
Number of Cells: max. 18 cells
Range: velocity ± 5,3 m/s
water level (ultrasonic) 0,04-1,3 m
expandable via external
4-20 mA sensor
Accuracy: ± 1% of measured value
for v and h (ultrasonic)
± 2% for discharge
Cable Length: max. 80 m
Display: 4 lines, 20 characters
Keyboard: 5 keys
Datalogger: 16 GB Micro SD card
Communication: RS-232, MODBUS, (RS232 or RS485),
WLAN, GPRS
Inputs: max. 8 x 4-20 mA
Outputs: max. 4 x 4-20 mA
4 x Relay, 2 x Pulse
Power Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC
Approval: ATEX (option)
Enclosure: ABS, wall mounted