Products / Flow Measurement / Closed Pipe Systems / Ductus TT
Ductus TT
Ultrasonic multipath flowmeter.
For pipes with a diameter of more than half a meter, acoustic flow measurement systems have long established themselves as a reliable and convenient measurement method. Measurements in several planes are a recommended method to determine the efficiency of the turbine without the need for calibration meeting the latest international standards. Fixed installed equipment form the basis for verifying the efficiency. A deterioration of efficiency can be detected right away and therefore corrections can be initiated at an early stage.
Acoustic Paths: | 1 – 8 |
Range: | ± 20 m/s |
Display: | 4 lines, 20 characters |
Datalogger: | internal, sampling interval user selectable |
Communication: | RS-232, MODBUS, Ethernet, USB |
Inputs: | max. 8 x 4-20 mA |
Outputs: | max. 4 x 4-20 mA 2 x Relay, 2 x Pulse |
Power Supply: | 85-264 VAC (50-60 Hz) or 12 VDC |
Battery Backup: | integrated, 2 Ah |
Enclosure: | Aluminium, wall mounted |
Dimensions: | 400 x 500 x 160 mm (WxHxD) |
Feedthrough 45
Various transducers are available. Internal mount assemblies which can be fixed directly to the wall. The transducers are aligned by rotating them in their mounting into a predefined position and then fixed in place by tightening Feedtrough assemblies for installation through exposed penstock walls with access to the interior and exterior of the penstock flow meter section.
Frequency: | 120 kHz |
Beam Width: | 10° (-3dB) |
Configuration: | IEC41 / ASMEPTC 18 |
Pipe Diameter: | 0,3 m to 15 m |
Pipe Wall Thickness: | up to 40 mm |
Pressure Rate: | 60 bar – other ranges upon request |
Material: | Stainless Steel |
Cable: | twisted pair with shield |
Cable Length: | max. 1000 m |
Temperature Range: | -20° to 60°C |
Installation: |
When pipe can be dewatered for installation. Designed to allow removal of the entire transducer for repair, replacement or cleaning without dewatering the pipe. |
Feedthrough 35
Various transducers are available. Internal mount assemblies which can be fixed directly to the wall. The transducers are aligned by rotating them in their mounting into a predefined position and then fixed in place by tightening Feedtrough assemblies for installation through exposed penstock walls with access to the interior and exterior of the penstock flow meter section.
Frequency: | 120 kHz |
Beam Width: | 10° (-3dB) |
Configuration: | IEC41 / ASMEPTC 18 |
Pipe Diameter: | 0,3 m to 15 m |
Pipe Wall Thickness: | up to 40 mm |
Pressure Rate: | 60 bar – other ranges upon request |
Material: | Stainless Steel |
Cable: | twisted pair with shield |
Cable Length: | max. 1000 m |
Temperature Range: | -20° to 60°C |
Installation: |
When pipe can be dewatered for installation. Designed to allow removal of the entire transducer for repair, replacement or cleaning without dewatering the pipe. |
Transducer Internal Mount
Frequency: | 200 kHz |
Beam Width: | 18° (-3dB) |
Configuration: | IEC41 / ASMEPTC 18 |
Pipe Diameter: | min. 1000 mm |
Pipe Wall Thickness: | – |
Pressure Rate: | max. 100 bar |
Material: | Stainless Steel / Polyamid |
Cable: | twisted pair with shield |
Cable Length: | max. 1000 m |
Temperature Range: | -10° to 60°C |
Installation: | From the inside |